Location : Main > Our Products > Electrical Steel > Non-Oriented Electrical Steel
















1. PN-Core

The non-oriented electrical steel features even magnetic properties in the rolling direction and in other directions. They are widely used for iron core materials of rotating machines ranging from large-size power generators to small-size precision electric motors. They are also desirable for iron core of small-size power transformers.

2. PNM-Core

It is utilized as steel material for magnetic switches and improved in wear resistance and residual magnetism.

3. PN-Core

Standard Sizes

Product
Grade
Thickness
(mm)
Width (mm)
Inner Coil Diameter
(mm)
Available Width
Standard Width
PN-Core
(Coil)
35PN210, 35PN230, 35PN250, 35PN270,
35PN300, 35PN360, 35PN440
0.35
850-1120
1000
1100
508-520
(Standard:508)
50PN250, 50PN270, 50PN290, 50PN310,
50PN350, 50PN400, 50PN470
0.50
65PN290, 65PN310, 65PN350, 65PN400,
65PN470
0.65
50PN600, 50PN700, 50PN800, 50PN1000, 50PN1300
0.50
850-1250
1000
1100
1200
65PN600, 65PN700, 65PN800, 65PN1000, 65PN1300
0.65
Remark: For information on non-standard widths, please contact us.

Surface Coating

Generally, a combination of C-6 coating is applied. For information regarding C-9 coating , please contact us.

Specifications

Magnetic properties and lamination factors
Grade
Thickness
(mm)
Density
(g/cm³)
Core LossW/kg
Induction T
Lamination
Factor
(%)
W15/50
B50
35PN210
35PN230
35PN250
35PN270
35PN300
35PN360
35PN440
0.35
7.60
7.60
7.60
7.65
7.65
7.65
7.70
2.10 and under
2.30 and under
2.50 and under
2.70 and under
3.00 and under
3.60 and under
4.40 and under
1.62 and over
1.62 and over
1.62 and over
1.62 and over
1.62 and over
1.63 and over
1.65 and over
95.0
50PN250
50PN270
50PN290
50PN310
50PN350
50PN400
50PN470
50PN600
50PN700
50PN800
50PN1000
50PN1300
0.50
7.60
7.60
7.60
7.65
7.65
7.65
7.70
7.75
7.80
7.85
7.85
7.85
2.50 and under
2.70 and under
2.90 and under
3.10 and under
3.50 and under
4.00 and under
4.70 and under
6.00 and under
7.00 and under
8.00 and under
10.00 and under
13.00 and under
1.62 and over
1.62 and over
1.62 and over
1.62 and over
1.62 and over
1.63 and over
1.64 and over
1.66 and over
1.70 and over
1.70 and over
1.70 and over
1.70 and over
96.0
65PN290
65PN310
65PN350
65PN400
65PN470
65PN600
65PN700
65PN800
65PN1000
65PN1300
0.65
7.60
7.65
7.65
7.65
7.70
7.75
7.80
7.85
7.85
7.85
2.90 and under
3.10 and under
3.50 and under
4.00 and under
4.70 and under
6.00 and under
7.00 and under
8.00 and under
10.00 and under
13.00 and under
1.62 and over
1.62 and over
1.62 and over
1.63 and over
1.64 and over
1.66 and over
1.70 and over
1.70 and over
1.70 and over
1.70 and over
97.0

Remark: Above test is conducted in accordance to IEC60404-2 or (JIS C 2550-2000) with half of the specimen in the rolling direction and the other half at a right angle to the rolling direction.

Dimension & Shape Tolerance

Width
(mm)
Thickness
(mm)
Thickness Tolerance
(mm)
Camberness
(mm)
Width Tolerance
(mm)
Linear Measure
(standard 2m )
(mm)
1000 and under
0.35
0.50
0.65
±0.035
±0.040
±0.052
0.02 and under
0.03 and under
0.04 and under
+1.5
0
1.0and under
over 1000
0.35
0.50
0.65
±0.035
±0.040
±0.052
0.03 and under
0.04 and under
0.04 and under
+1.5
0

Remark: Camberness means the difference between the thickness of the center and the thickness of a spot 15mm from the edge.

Typical Electrical and Magnetic Property

Grade
Thickness
(mm)
Dendity
(g/cm³)
Resistivity
Ω·m(× 10-8)
Core Loss (W/kg)
Induction(T)
W10/50
W15/50
W10/60
W15/60
B25
B50
35PN210
35PN230
35PN250
35PN270
35PN300
35PN360
35PN440
0.35
7.60
7.60
7.60
7.65
7.65
7.65
7.70
59
59
55
52
45
45
42
0.84
0.89
0.96
1.02
1.08
1.25
1.39
2.04
2.10
2.25
2.40
2.53
2.80
3.08
1.03
1.07
1.17
1.28
1.38
1.55
1.73
2.53
2.60
2.85
3.00
3.18
3.45
3.82
1.56
1.57
1.57
1.58
1.59
1.59
1.62
1.65
1.66
1.66
1.67
1.69
1.69
1.71
50PN250
50PN270
50PN290
50PN310
50PN350
50PN400
50PN470
50PN600
50PN700
50PN800
50PN1000
50PN1300
0.50
7.60
7.60
7.60
7.65
7.65
7.65
7.70
7.75
7.80
7.85
7.85
7.85
59
59
56
53
50
45
42
34
30
17
17
17
1.00
1.05
1.09
1.21
1.30
1.41
1.64
1.98
2.62
2.93
3.20
3.75
2.37
2.50
2.60
2.70
2.93
3.18
3.55
4.40
5.55
6.26
6.80
7.56
1.31
1.35
1.45
1.55
1.63
1.82
2.06
2.49
3.30
3.63
4.10
4.75
3.08
3.22
3.35
3.46
3.74
4.01
4.56
5.63
7.03
7.94
8.62
9.54
1.57
1.57
1.58
1.59
1.60
1.61
1.61
1.62
1.64
1.66
1.67
1.67
1.67
1.67
1.67
1.68
1.69
1.70
1.70
1.71
1.72
1.74
1.75
1.75

Remark: Core loss and magnetic density tests are conducted in accordance to the IEC 60404-2 or JIS C 2550-2000.

 

Typical Mechanical Property and Lamination Factor

Grade
Thickness
(mm)
Tensile strength
(N/m²)
Yield Point
(N/m²)
Elongation
(%)
Longitude
(%)
Lamination
Factor
(%)
L
C
L
C
L
C
35PN210
35PN230
35PN250
35PN270
35PN300
35PN360
35PN440
0.35
567
550
490
485
485
460
405
587
570
510
500
500
470
415
450
440
378
365
360
330
275
460
450
388
375
370
340
285
14
16
18
21
22
25
26
16
18
20
23
24
27
29
225
220
205
190
185
170
150
97.5
50PN250
50PN270
50PN290
50PN310
50PN350
50PN400
50PN470
50PN600
50PN700
50PN800
50PN1000
50PN1300
0.50
580
550
510
495
495
480
410
395
385
375
370
350
590
570
530
510
510
490
420
405
395
385
380
360
470
450
385
380
370
355
265
260
270
270
265
250
480
460
395
390
380
365
375
270
280
280
275
260
19
20
23
26
26
28
34
37
38
39
40
42
22
23
25
28
28
30
36
39
39
40
41
43
223
220
195
185
185
177
143
130
120
115
113
105
98.0
                    Note : 1. Tests are conducted in accordance with IEC60404-2 (or JIS C 2550-2000).
                   2. L : Specimens taken longitudinal to the rolling direction
                   C : Specimens taken transverse to the rolling direction

4. PNM-Core

Standard Size

Classification
Standard
Thickness(mm)
Width(mm)
Available size
Standard size
PNM-Core
(Coil)
65PNM540
0.65
850-1100
1000
1050
1100
70PNM500
0.70

Remark: Inner diameter: 508-520mm(standard:508mm).   For non-standard sizes, please contact us.

Insulation Coating

Only C-6 combined coating (organic/inorganic) can be done with PNM-Core. The coating is done on the thick film of C-6B.

Specifications

Magnetic properties and lamination factor
Classification
Thickness
(mm)
Density
(g/cm³)
Core loss
Induction (T)
Lamination Factor
(%)
W15/50
B50
65PNM540
0.65
7.70
5.40
1.66
97 and over
70PNM500
0.70
7.65

5.00

1.65

Remark: Above test is conducted in accordance to IEC 60404-2 or (JIS C 2550-2000) with half of the specimen in the rolling direction and the other half at a right angle to the rolling direction.

Tolerance

Width
Thickness
(mm)
Thickness Tolerance
(mm)
Camberness
(mm)
Width Tolerance
(mm)
Linear Measure
(standard length 2m)
(mm)
1,000 and under
0.65
0.70
±0.052
±0.056
0.04 and under
+1.5
0
1.0 and under
over 1,000
0.65
0.70
±0.052
±0.056

Remark: Camberness means the difference in the thickness between the center and a spot 15mm from the edge.

Typical Electrical and Magnetic Property

Grade
Thickness
(mm)
Density
(g/cm³)
Resistivity
(-cm)
Core Loss (w/kg)
Induction (T)
W10/50
W15/50
W10/60
W15/60
B25
B50
65PNM540
0.65
7.70
42
1.96
4.14
2.52
5.44
1.65
1.73
70PNM500
0.70
7.65
44
1.89
3.99
2.42
5.25
1.61
1.70

Remark: Above test is conducted in accordance to IEC 60404-2 or (JIS C 2550-2000) with half of the specimen in the rolling direction and the other half at a right angle to the rolling direction.

Typical Mechanical Property and Lamination Factor

Grade
Thickness
(mm)
Tensile Strength
(N/mm²)
Yield Point
(N/mm²)
Elongation
(%)
Longitude
(Hv 1)
Lamination factor
(%)
L
C
L
C
L
C
65PNM540
0.65
425
435
285
295
30
32
150
98.0
70PNM500
0.70
490
500
365
375
29
31
175

Remark: Above test is conducted in accordance to IEC 60404-2 or JIS C 2550-2000.
L is the specimen taken in a longitudinal rolling direction, while C is taken perpendicular to the rolling direction.

 

 Copyright © POSCO, All rights reserved. Contact steelinfo@Steel-N.com for more information