This product improved the grain by adding boron and
enhanced the non-resistance by including A1.
Used for motors in electrical appliances, this
electrical sheet has low core loss from undergoing the SRA
process at the customer's plant.
2.Product Status
Product
Standard
Usage
Avaliable Sizes
Remark
Electrical Steel Sheet
50PNA1650*
- Motor core for home appliances
(refrigerators, air conditioners, etc.)
- EI core
Thickness: 0.50mm
Width: 1000,1100,1200 mm
When heat treated by customer,
core loss improves by about 30%
* 0.5mmt, POSCO Non-oriented annealed, Core Loss ≤
16.5 W/kg
3. Level of Quality
Standard
Specified Core Loss (W/Kg)
Magnetic Induction (Tesla)
Remark
W15/50
W15/60
50PNA1650
≤ 6.0
≤ 8.0
≥ 1.68
Specified value after the SRA
* SRA (Stress Relief Annealing) : Under the atmosphere
of 100% N2 constant heat of 790°Cx80 min.
* W/Kg (Unit of core loss): Watt/Kg, T (Unit of
magnetic induction): Tesla
* W15/50(60): Core loss value at the frequency of
50(60)Hz and the magnetic induction of 1.5 Tesla
* B50: Magnetic induction at the magnetic force
of 5000 A/m