1. Product Characteristics
 |
 |
 |
|
 |
|
| Due
a sudden rise in temperature, the tensile
strength of general steel deteriorates
rapidly in case of fire in steel-framed
structures. Therefore the law
stipulates fireproof coating on the
steel framework to ensure structural
safety. However the trend is to
forgo fireproof coating to facilitate
construction. As a measure to
counter this trend, fireproof
steel was developed to maintain high
strength in high temperatures. |
|
|
 |
|
 |
|
|
2. Product Status
 |
|
Product
|
Standard
|
Usage
|
Available Sizes
|
|
Plate
|
FR490B
|
Building
structures, parking lots, etc. |
Thickness: 6 ~ 70 mm
|
|
|
3. Level of Quality
 |
|
Classification
|
Standard
|
Chemical Composition
|
Yield Strength
|
|
Room Temperature
|
300°C
|
600°C
|
|
FR Steel
|
FR-490B
|
Cr-Mo
|
≥ 33kg/mm²
|
≥ 22kg/mm²
|
≥ 22kg/mm²
|
|
General Steel
|
SM490B
|
C-Mn
|
≥ 33kg/mm²
|
≥ 22kg/mm²
|
-
|
|
|
|